HYDRANT VALVE, SINGLE OUTLET STAINLESS STEEL-SS316, AS PER IS:5290
Hydrant valves (also called Landing valves) provide the means to draw water for fire fighting from the Fire water piping network. They are normally mounted onto stand posts, fitted on the fire water network.Brief Description : Hydrant Valve, as per IS:5290 Type A, made of Stainless Steel (SS316), having 75 mm flanged inlet, and 63 mm Female Instantaneous outlet, provided with C.I. hand wheel for operation, and PVC blank cap with chain. Body duly painted with 2 coats of superior quality paint. H.P. tested to 21 kgf/cm² (body) and 14 kgf/cm² (seat). Flow 900 lpm (min) at 7 kgf/cm²
HYDRANT VALVE, DOUBLE OUTLET STAINLESS STEEL-SS316, AS PER IS:5290
valves (also called Landing valves) provide the means to draw water for fire fighting from the Fire water piping network. They are normally mounted onto stand posts, fitted on the fire water network.Brief Description : Hydrant Valve (Double headed), as per IS: 5290, made of Stainless Steel (SS316), having 100 mm flanged inlet, and 2 Nos. 63 mm Female Instantenous outlets, C.I. hand wheels for hydrant operation, and PVC blank caps with chain. Body duly painted with 2 coats of superior quality paint. H.P. tested to 21 kgf/cm2 (body) and 14 kgf/cm2 (seat). Flow 1800 lpm (min) at 7 kgf/cm2.
HOSE REEL (VERTICAL) MILD STEEL, SWINGING TYPE, AS PER IS:884
Hose Reels are first aid fire fighting equipment, meant for use by untrained/semi-trained personnel at the incipient stages of the fire. Hose Reels are strategically located at various locations, and fed by pressurized supply of water. A rubber/ PVC hose of 1” or ¾” dia. (of 30/ 36 mtrs length) is wound on the revolving drum, and connected to a discharge nozzle.Brief Description : AAAG Hose Reel (Swinging type), As per IS:884, made of M.S. construction, having Rubber/ PVC hose of 1”/ ¾“ dia. of 30/36 mtrs. length, and fitted with Gunmetal/Stainless Steel Shut off nozzle. The Hose Reel shall provide a good range jet at the specified pressure for effective fire fighting.
SHORT BRANCH PIPE WITH NOZZLE GUNMETAL, AS PER IS:903
Short Branch Pipe with Nozzle is the most common fire fighting nozzle in use in the country. The nozzle gives a solid jet and different sizes (bore) of nozzles can be fitted to the branch body depending upon operational requirementBrief Description : AAAG Short Branch Pipe with Nozzle, as per IS: 903, made of Gun Metal (Lead Tin Bronze), fitted with 6/ 12/16/20/25 mm bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm2 for 2.5 minutes.
FIRE BRIGADE INLET (4 WAY) SS316, 63 mm, HORIZONTAL DESIGN
Fire Brigade Inlet (also called Pumping In Breech) allows Fire Tenders (Pumpers) to pump in water into the Dry Riser/ Wet Riser/ Sprinkler system piping using external water sources such as hydrants. Fire Brigade Inlet is fitted with required number of standard Male Instantenous inlets to feed the Riser pipe depending upon size.Brief Description : AAAG Fire Brigade Inlet (Pumping in Breech), Horizontal design, made of Stainless Steel (SS316), having 4 Nos. 63 mm size Male Instantaneous inlets (with NRV), and 150 mm size flanged outlet, suitable for connection to Dry Riser piping. Fire Brigade inlet body shall be provided with drain valve for draining water after operation.
HVLR MONITOR SS316, 75 mm WATERWAY, GEARED SWIVEL
HVLR monitors are used for high volume applications and produce superior, long reaching streams. These monitors can be used for water or foam application, depending upon the nozzle fitted on the monitor. They can be fixed onto Monitor posts, or can be mounted on custom-built trailers.Brief Description : AAAG HVLR monitor, nominal waterway size 75mm, flow capacity 2840 lpm (min) at 7 kg/cm2 inlet pressure. The monitor shall be constructed of Stainless Steel (SS316), with Geared Swivel Joints & Hand wheels, have suitable inlet flange and nozzle of specified type & capacity. Monitor shall give good hydraulic performance and range.
Fire Fighting Pump Room Main Pump, Sprinkler Pump, Jockey Pump
The Hydrant System comprises of AC motor driven pump sets with all required accessories including valves, instrumentation and controls etc. Complete in all respects. An automatic hydrant system is furnished covering the areas completely from independent.Pipe work from the fire water pump set.The hydrant pipe work is remaining pressurized through the proposed jockey pump taking care of any leakages in the system pipe lines, valves and fittings.The hydrant system is kept charged by pressurized water at approx. 7 Kg. Cm.Sq. at all times. In the event of fire when any of the hydrant valves in the net work is opened, the resultant fall in pressure system is enabling starting the AC MOTOR driven fire water pumpingset through pressure switches automatically. One diesel engine pump shall be standby pump serving hydrant system. Apart from the automatic starting of the pump sets, provision shall be kept for manual starting also. Shutting down of the pump setsshall be manual
.